AGV Electromagnetic Flow Meters for Agricultural Applications - Máy đo lưu lượng điện từ AGV cho các ứng dụng nông nghiệp
Xuất sứ: Japan
Nhà cung cấp: Pites
Hãng sản xuất: Aichi Tokei Denki
AGV Electromagnetic Flow Meters for Agricultural Applications | Máy đo lưu lượng điện từ AGV cho các ứng dụng nông nghiệp Aichi Tokei Nhật Bản chính hãng mới 100% có COCQ
Click vào đây nếu bạn có thiết bị muốn sửa chữa!!!
Specifications
Standard specifications (Diameter 200 – 350 mm)
Diameter (mm) | 200 | 250 | 300 | 350 | |
---|---|---|---|---|---|
Measurement range *1 | Flow velocity | 0.1 – 5m/s | |||
Maximum flow rate Qmax (L/s) | 170 | 254 | 375 | 459 | |
Accurate lower flow rate Qc (L/s) | 3.4 | 5.3 | 7.5 | 9.4 | |
Accumulated accuracy (%) | ■Diameter 200 – 350 mm | ||||
Operating pressure | 2 MPa (Flange type: 1 MPa, Saddle type: 0.5 MPa) | ||||
Test pressure | 4 MPa (Flange type: 2 MPa, Saddle type: 1 MPa) | ||||
Fluid temperature range | 0 to +40℃ | ||||
Environment temperature range | -10 to +50℃ | ||||
Minimum conductivity | 50 µS/cm * 50 µS/cm or more for normal tap water | ||||
Display * 2 | Integrated flow rate (unit L), Instantaneous flow rate (unit L/s), Empty fluid indication, Battery voltage drop indication | ||||
Power source | Built-in lithium battery, Battery life: about 20 years (Under an environmental temperature of 20°C) | ||||
Piping method | Sensor installation part: Flange type: Use existing measuring pipes (Dedicated flange adaptor or dedicated saddle) Measuring short piping: Both sides/one side flanges (Clean water/JIS10K/JIS20K) |
||||
External output *3 | (1) No output | No output | |||
(2) Code output *4 | SS format code output, accumulated and instantaneous flow rate (transmitted every 1.8 seconds). | ||||
(3) Pulse output | Open drain pulse output Pulse ON time: 100±10 ms Pulse unit: 100 L /P, 1 m3/P, (10 m3/P) Maximum load: 30 VDC, 20 mA |
||||
(4) 8-bit telegram output | 2-wire: 8-bit telegram output 4-wire: 8-bit electronic output + Open drain pulse output (The same specifications as the above pulse output) |
||||
Waterproof structure | IP 68 (Can be used continuously under water.) |
Standard specifications (Diameter 400 – 800 mm)
Diameter (mm) | 400 | 450 | 500 | 500 | 700 | 800 | |
---|---|---|---|---|---|---|---|
Measurement range *1 | Flow velocity | 0.1 – Sm/s | |||||
Maximum flow rate Qmax (L/s) |
617 | 785 | 970 | 1398 | 1898 | 2493 | |
Accurate lower flow rate Qc (L/s) |
12.3 | 15.7 | 19.4 | 28.0 | 38.0 | 49.9 | |
Accumulated accuracy (%) | ■Diameters400 – 800mm | ||||||
Operating pressure | 2 MPa (Flange type: 1 MPa, Saddle type: 0.5 MPa) | ||||||
Test pressure | 4 MPa (Flange type: 2 MPa, Saddle type: 1 MPa) | ||||||
Fluid temperature range | 0 to +40℃ | ||||||
Environment temperature range | -10 to +50℃ | ||||||
Minimum conductivity | 50 µS/cm *50 µS/cm or more for normal tap water | ||||||
Display * 2 | Integrated flow rate (unit L), Instantaneous flow rate (unit L/s), Empty fluid indication, Battery voltage drop indication | ||||||
Power source | Built-in lithium battery, Battery life: about 20 years (Under an environmental temperature of 20°C) | ||||||
Piping method | Sensor installation part: Flange type: Use existing measuring pipes (Dedicated flange adaptor or dedicated saddle) Measuring short piping: Both sides/one side flanges (Clean water/JIS10K/JIS20K) |
||||||
External output *3 | (1) No output | No output | |||||
(2) Code output *4 | SS format code output, accumulated and instantaneous flow rate (transmitted every 1.8 seconds). | ||||||
(3) Pulse output | Open drain pulse output Pulse ON time: 100±10 ms Pulse unit: 100 L/P, 1 m3/P, (10 m3/P) Maximum load: 30 VDC, 20 mA |
||||||
(4) 8-bit telegram output | 2-wire: 8-bit telegram output 4-wire: 8-bit electronic output + Open drain unit pulse output (The same specifications as the above pulse output) |
||||||
Waterproof structure | IP 68 (Can be used continuously under water.) |
Avoid using the meter in such a corrosive gas environment as chlorine and hydrogen sulfide.
Please contact us if you want to measure fluid other than water.
*1. The flow rate is calculated at “Sch 10S.”
*2. Consider the instantaneous flow rate as a reference.
*3. For the output unit, code output unit, pulse output (with a built-in lithium battery with 10 years lifespan under an average environmental temperature of 20°C)
and 8-bit telegram communication (with a built-in lithium battery with 8 years lifespan under an average environmental temperature of 20°C) are available, and
it comes with cables. The external output can only be changed by replacing the output unit.
*4. A dedicated receiver is available.
Dimensions
Installation position
Installation example
Installation of closed piping
Replacing our impeller-type flow meters
・S