5P3B1F-AAIBAHBGACBD5K3DA1
Proline Promag P 300
Electromagnetic flowmeter
The flowmeter for highest medium temperatures with a compact, easily accessible transmitter
Application
• The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
• Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
Device properties
• Nominal diameter: max. DN 600 (24")
• All common Ex approvals
• Liner made of PTFE or PFA
• Compact dual-compartment housing with up to 3 I/Os
• Backlit display with touch control and WLAN access
• Remote display available
Your benefits
- Versatile applications - wide variety of wetted materials
- Energy-saving flow measurement - no pressure loss due to cross-section constriction
- Maintenance-free - no moving parts
- Full access to process and diagnostic information - numerous, freely combinable I/Os and fieldbuses
- Reduced complexity and variety - freely configurable I/O functionality
Video Demo
Configure your selected product
5P3BXX-XXXXXXXXXXXXXXXXXX+XXXXXXXXXXX
Promag P 300, 5P3B15, DN15 1/2"
Promag P 300, 5P3B1F, DN150 6"
Promag P 300, 5P3B1H, DN100 4"
Promag P 300, 5P3B1Z, DN125
Promag P 300, 5P3B25, DN25 1"
Promag P 300, 5P3B2F, DN250 10"
Promag P 300, 5P3B32, DN32
Promag P 300, 5P3B3F, DN350 14"
Promag P 300, 5P3B3H, DN300 12"
Promag P 300, 5P3B40, DN40 1 1/2"
Promag P 300, 5P3B4F, DN450 18"
Promag P 300, 5P3B4H, DN400 16"
Promag P 300, 5P3B50, DN50 2"
Promag P 300, 5P3B5H, DN500 20"
Promag P 300, 5P3B65, DN65
Promag P 300, 5P3B6H, DN600 24"
Promag P 300, 5P3B80, DN80 3"
Required
010Approval; Transmitter + Sensor:
AA |
|
0 | ||||
BB |
ATEX+IECEx; Z1/21, Ex de, IIC/IIIC
|
0 | ||||
BD |
ATEX+IECEx; Z1/21, Ex d, IIC/IIIC
|
0 | ||||
BS |
ATEX+IECEx; Z2, IIC
|
0 | ||||
CD |
CSA C/US; Cl.I,II,III Div.1, XP, Gr.A-G
|
0 | ||||
CS |
CSA C/US; Cl.I Div.2, NI
|
0 | ||||
CZ |
CSA C/US; Z2, IIC
|
0 | ||||
C2 |
CSA C/US; Z1/21, Ex de, IIC/IIIC
|
0 | ||||
C4 |
CSA C/US; Z1/21, Ex d, IIC/IIIC
|
0 | ||||
GB |
EAC; Z1/21, Ex de, IIC/IIIC
|
0 | ||||
GD |
EAC; Z1/21, Ex d, IIC/IIIC
|
0 | ||||
GR |
EAC; Non-hazardous area
|
0 | ||||
GS |
EAC; Z2, IIC
|
0 | ||||
JD |
JPN; Z1, Ex d, IIC
|
0 | ||||
MB |
INMETRO; Z1/21, Ex de, IIC/IIIC
|
0 | ||||
MD |
INMETRO; Z1/21, Ex d, IIC/IIIC
|
0 | ||||
MS |
INMETRO; Z2, IIC
|
0 | ||||
NB |
NEPSI; Z1/21, Ex de, IIC/IIIC
|
0 | ||||
ND |
NEPSI; Z1/21, Ex d, IIC/IIIC
|
0 | ||||
NS |
NEPSI; Z2, IIC
|
0 |
015 Power Supply:
D
|
24VDC | 0 | ||||
E |
100-230VAC
|
0 | ||||
I |
100-230VAC/24VDC
|
0 | ||||
9 |
Special version, TSP-no. to be spec.
|
On request |
020 Output; Input 1
BA
|
4-20mA HART | |||||
CA |
4-20mA HART Ex-i passive
|
0 | ||||
CC |
4-20mA HART Ex-i active
|
0 | ||||
GA |
PROFIBUS PA
|
0 | ||||
HA |
PROFIBUS PA Ex-i
|
0 | ||||
LA |
PROFIBUS DP
|
0 | ||||
MA |
Modbus RS485
|
0 | ||||
NA |
EtherNet/IP 2-port switch integrated
|
0 | ||||
RA |
PROFINET 2-port switch integrated
|
0 | ||||
SA |
FOUNDATION Fieldbus
|
0 | ||||
TA |
FOUNDATION Fieldbus Ex-i
|
0 | ||||
99 |
Special version, TSP-no. to be spec.
|
On request |
021 Output; Input 2:
A
|
W/o | |||||
B |
4-20mA
|
0 | ||||
C |
4-20mA Ex-i passive
|
0 | ||||
D |
Configurable I/O default off
|
0 | ||||
E |
Pulse/freq./switch output
|
0 | ||||
F |
Pulse output, phase-shifted
|
0 | ||||
G |
Pulse/freq./switch output Ex-i passive
|
0 | ||||
H |
Relay
|
0 | ||||
I |
4-20mA input
|
0 | ||||
J |
Status input
|
0 | ||||
9 |
Special version, TSP-no. to be spec.
|
On request |
022 Output; Input 3:
A
|
W/o | |||||
B |
4-20mA
|
0 | ||||
C |
4-20mA Ex-i passive
|
0 | ||||
D |
Configurable I/O default off
|
0 | ||||
E |
Pulse/freq./switch output
|
0 | ||||
F |
Pulse output, phase-shifted
|
0 | ||||
G |
Pulse/freq./switch output Ex-i passive
|
0 | ||||
H |
Relay
|
0 | ||||
I |
4-20mA input
|
0 | ||||
J |
Status input
|
0 | ||||
9 |
Special version, TSP-no. to be spec.
|
On request |
030Display; Operation:
A
|
W/o; via communication | 0 | ||||
F |
4-line illum.; touch control
|
0 | ||||
G |
4-line illum.; touch control + WLAN
|
0 | ||||
M |
W/o; prepared for remote display
|
0 | ||||
O |
Remote display 4-line illum., 10m/30ft cable; touch control
|
0 | ||||
9 |
Special version, TSP-no. to be spec.
|
On request |
040Housing:
A
|
Alu, coated | |||||
9 |
Special version, TSP-no. to be spec.
|
On request |
050Electrical Connection:
A
|
Gland M20 | |||||
B |
Thread M20
|
0 | ||||
C |
Thread G1/2
|
0 | ||||
D |
Thread NPT1/2
|
0 | ||||
L |
Thread NPT1/2 + 1x plug M12x1
|
0 | ||||
M |
Gland M20 + 1x plug 7/8"
|
0 | ||||
N |
Gland M20 + 1x plug M12x1
|
0 | ||||
P |
Thread G1/2 + 1x plug M12x1
|
0 | ||||
R |
Gland M20 + 2x plug M12x1
|
0 | ||||
S |
Thread NPT1/2 + 2x plug M12x1
|
0 | ||||
T |
Thread G1/2 + 2x plug M12x1
|
0 | ||||
U |
Thread M20 + 1x plug M12x1
|
0 | ||||
V |
Thread M20 + 2x plug M12x1
|
0 | ||||
3 |
Thread M20 + 1x plug 7/8"
|
0 | ||||
4 |
Thread G1/2 + 1x plug 7/8"
|
0 | ||||
5 |
Thread NPT1/2 + 1x plug 7/8"
|
0 | ||||
6 |
JPN Ex d Thread G1/2
|
0 | ||||
9 |
Special version, TSP-no. to be spec.
|
On request |
060Liner:
E |
PTFE
|
|||||
9 | Special version, TSP-no. to be spec. |
|
On request |
070Process Connection:
A1K
|
Cl.150, carbon steel, flange ASME B16.5 |
|
||||
A1S |
Cl.150, stainl. steel, flange ASME B16.5
|
+5
|
||||
A2K |
Cl.300, carbon steel, flange ASME B16.5
|
+5
|
||||
A2S |
Cl.300, stainl. steel, flange ASME B16.5
|
+5
|
||||
D5K |
PN40, carbon steel, flange EN1092-1
|
0 | ||||
D5S |
PN40, stainl. steel, flange EN1092-1
|
+5
|
||||
N4K |
20K, carbon steel, flange JIS B2220
|
+5
|
||||
N4S |
20K, stainl. steel, flange JIS B2220
|
+5
|
||||
999 |
Special version, TSP-no. to be spec.
|
On request |
075Electrodes:
G
|
1.4435/316L, bullet nose | 0 | ||||
H |
Alloy C22, bullet nose
|
0 | ||||
0 |
1.4435/316L
|
0 | ||||
1 |
Alloy C22
|
0 | ||||
2 |
Tantalum
|
0 | ||||
3 |
Platinum, meas. electrode only
|
+10
|
||||
4 |
Tantalum, meas. electrode only
|
+10
|
||||
5 |
Platinum
|
0 | ||||
8 |
Titanium
|
0 | ||||
9 |
Special version, TSP-no. to be spec.
|
On request |
Optional
500>Operation Language Display:
AA |
English
|
0 | ||||
AB |
German
|
0 | ||||
AC |
French
|
0 | ||||
AD |
Spanish
|
0 | ||||
AE |
Italian
|
0 | ||||
AF |
Dutch
|
0 | ||||
AG |
Portuguese
|
0 | ||||
AH |
Polish
|
0 | ||||
AI |
Russian
|
0 | ||||
AJ |
Turkish
|
0 | ||||
AK |
Chinese simplified
|
0 | ||||
AL |
Japanese
|
0 | ||||
AM |
Korean
|
0 | ||||
AN |
*Arabian
|
On request | ||||
AO |
Bahasa
|
0 | ||||
AP |
*Thai
|
On request | ||||
AQ |
Vietnamese
|
0 | ||||
AR |
Czech
|
0 | ||||
AT |
Swedish
|
0 |
520>>Sensor Option:
|
Harsh environment | +3 | ||||
CG |
Extended neck for insulation
|
0 | ||||
C9 |
Special version, TSP-no. to be spec.
|
On request |
530>>Customized parameterization
DA
|
Output 1 | 0 | ||||
DB |
Output 2
|
0 | ||||
DG |
Totalizer
|
0 | ||||
DH |
Display; Totalizer
|
On request | ||||
DM |
Output 3
|
0 | ||||
D9 |
Special version, TSP-no. to be spec.
|
On request |
570>>Service:
HC
|
*PWIS free (Version A), PWIS = paint-wetting impairment substances | On request | ||||
HD |
*PWIS free (Version B), PWIS = paint-wetting impairment substances
|
On request | ||||
HE |
*PWIS free (Version C), PWIS = paint-wetting impairment substances
|
On request | ||||
I7 |
Product documentation on paper
|
0 | ||||
I9 |
Special version, TSP-no. to be spec.
|
On request |
580>>Test, Certificate:
JA
|
Inspection certificate 3.1, EN10204 (material certificate meas. tube+flange) | 0 | ||||
JB |
Pressure test, internal procedure, test report
|
0 | ||||
JL |
PMI test, internal procedure (meas. tube+flange), test report
|
On request | ||||
K9 |
Special version, TSP-no. to be spec.
|
On request |
590>>Additional Approval:
LA
|
SIL | 0 | ||||
LD |
CRN
|
0 | ||||
LF |
ABS marine approval
|
0 | ||||
LG |
LR marine approval
|
0 | ||||
LH |
BV marine approval
|
0 | ||||
LJ |
DNV GL marine approval
|
0 | ||||
L3 |
ACS drinking water approval
|
0 | ||||
L4 |
NSF 61 drinking water approval
|
0 | ||||
L5 |
NSF 61 drinking + warm water approval
|
0 | ||||
L9 |
Special version, TSP-no. to be spec.
|
On request |
610>>Accessory Mounted:
NB
|
Adapter RJ45 M12 (service interface) | 0 | ||||
N9 |
Special version, TSP-no. to be spec.
|
On request |
620>>Accessory Enclosed:
PB
|
Weather protection cover | 0 | ||||
P8 |
Wireless antenna for extended range
|
+5 | ||||
RA |
Mounting bracket, pipe 1"/2"
|
0 | ||||
R9 |
Special version, TSP-no. to be spec.
|
On request |
850>Firmware Version:
63
|
01.05.zz, Modbus RS485, DevRev06 | 0 | ||||
64 |
01.05.zz, HART, DevRev06
|
0 | ||||
65 |
01.01.zz, PROFINET
|
0 | ||||
66 |
01.01.zz, PROFIBUS PA
|
0 | ||||
67 |
01.01.zz, Modbus RS485, DevRev01
|
0 | ||||
68 |
01.01.zz, HART, DevRev01
|
0 | ||||
70 |
01.00.zz, PROFIBUS PA
|
0 | ||||
71 |
01.00.zz, PROFINET
|
0 | ||||
72 |
01.00.zz, FOUNDATION Fieldbus
|
0 | ||||
73 |
01.00.zz, EtherNet/IP
|
0 | ||||
74 |
01.00.zz, Modbus RS485
|
0 | ||||
75 |
01.00.zz, PROFIBUS DP, DevRev01
|
0 | ||||
76 |
01.00.zz, HART, DevRev01
|
0 |
895>>Marking:
|
Tagging (TAG), see additional spec. | 0 | ||||
Z2 |
Bus address, see additional spec.
|
0 |
Z1 |
Tagging (TAG), see additional spec.
|
0 | ||||
Z2 |
Bus address, see additional spec.
|
0 |
Z1 |
Tagging (TAG), see additional spec.
|
0 | ||||
Z2 |
Bus address, see additional spec.
|
0 |