low-flow-magnetic-inductive-flow-meters-for-water-like-liquids-3.png

MAG-VIEW MVM-060-PN

MAG-VIEW MVM-060-PA

Dich vụ sửa chữa, bảo dưỡng, cải tiến các hệ thống dây chuyền tự động công nghiệp

Low-Flow Magnetic Inductive Flow meters for water-like liquids

  • Compact, weatherproof (IP65) design
  • No moving parts (no mechanical wear)
  • Interference free operation
  • Independence to inlet/outlet pipework
  • Fast response
  • Free pipe cross section: low ΔP, insensitive to contamination
  • Analog output (4...20 mA)

Electromagnetic flow meters for low flow rates of water and aqueous solutions

MAG-VIEW instruments are electromagnetic inductive flow meters for electrically conductive liquids with a minimum conductivity of 50 μS/cm. The compact, weatherproof (IP65) flow meters do not contain any moving parts, cause virtually no pressure loss and can be mounted in any position, requiring no straight inlet or outlet runs.

MAG-VIEW flow meter model MVM-060-PA has a nominal diameter of DN10 for flow rates of 1...60 l/min, suited for operating pressures up to 16 bar(g). The instrument allows frequency and analog output (4...20 mA) proportional to the flow.

Technical specifications

Performance

Accuracy

±1,5% Rd, ±0,3% FS

Turndown

1:60

Signal output starting from

~ 0,9 l/min

Response time

< 800 ms

Flow indication

green LED, flow proportional flashing

Media

Water and other conductive liquids
(minimum conductivity of 50 μS/cm)

Reproducibility

1% FS

Medium temperature

5...90°C

Mounting

Any position, attitude insensitive

 

Mechanical parts

Material (wetted parts)

Electrodes: Stainless Steel 1.4571
Process connections: Stainless Steel 1.4571
Measuring pipe: PEEK-GF30
Gasket: EPDM

Housing

Aluminium pressure diecasted

Ingress protection (housing)

IP65

Diameter

DN10

Process connections (welded)

½" BSP male thread

Nominal pressure

PN16

 

Electrical properties

Power supply

24 VDC ±10 %

Power consumption

≤ 150 mA

Frequency output

   Pulse rate / K-factor
   Resolution
   Signal shape

   Signal current

 

500 pulses/l
2 ml/pulse
Square wave signal • duty cycle 50:50
Push-Pull • NPN open collector [o.c.] • PNP o.c.
≤ 100 mA, current limited

Analog output (option)

4...20 mA, max. load 250 Ω to GND

Electrical connection

5-pin-plug M12x1