Specification:

Model

HD-1100

HD-1150

HD-1650

HD-1200

HD-1250

HD-1750

HD-1201

HD-1251

HD-1202

HD-1252

HD-1300

HD-1350

HD-1301

HD-1351

HD-1302

HD-1352

HD-1400

HD-1450

HD-1500

HD-1550

Waterproof specifications/Equivalent to IPX5

 

 

 

 

 

 

Display

LCD

LCD with Backlight

LED

LCD with Backlight

Input connector

ASP model

: HD-1*O* /ANP model: HD-1*5«

 

 

 

 

 

Channel

ich

Input type

Thermocouple Input: Type E or K (HD-1*O*) /Type E.K.J.T or R (HD-1«5*) Not switchable

Signal source resistance

MAX 500 Q

Measurement range

•TABLE I

Measurement accuracy

•TABLE II

Reference junction compensation accuracy

±0.2*C at 25t ± 10’C (±0.4T at 77*F± 18’F]

Temperatire coefficient

±0.01 % Of F / S per 0 (±0.01% of F / s per T]

$ F / s : full scale

 

 

 

Environmental

Operation

0—40 °C

0—80%RH(Non condensing) [32~1O4’F. 0~80%RH (Non condensing) ]

 

 

Storage

-20—50'C. 0~85%RH(Non condensing) [-4—122T. 0—85%RH (Non condensing) ]

Battery rife

300h

300 h

150 h

150h

300h

150h

150 h

150 h

150 h

 

Dry battery

4 AA Alkaline batteries

Power supply

AC power

-

-

AC-Adaptor (Option)

-

AC-Adaptor (Option)

Samping rate

approx. 300ms

approx. 300ms*i

Plineariizer

Digital linearlizer method (Compliant with IEC 60584-1 (2013))

Dimensions

approx. 76(W) X 167(H) X 36(D) mm [Protruded parts excluded]

Weight

approx. 350g [Include Batteries]

 

 

Manual.Test report. Softcase. Hand strap.4 AA Alkaline batteries

Supplied accessories

 

 

Analog output cable

Alarm output cable

 

Commurfcafcxi cable.

 

 

 

 

-

Analog output cable

 

Software (AMS-100)

Analog output

 

 

imvrc

iomv/‘c

 

imvrc

IOmV/0

 

 

 

 

•TABLE III

•TABLE III

 

•TABLE III

•TABLE III

 

 

Alarm output

-

-

-

-

•TABLE IV

•TABLE IV

•TABLE IV

-

-

Memory function

-

-

-

-

-

-

-

-

•TABLE V

Compatible standards

CE Marking. RoHS

 
*Sampling period will be a user-selected time interval when time Interval is specified at 10 seconds or more.
TABLE I (Measurement range)

Thermocouple type

 

•F

TC Resolution

o.rc Resolution

TF Resolution

0.1T Resolution

E

-200- 8O0’C

 

-328 — 1472T

 

K

-200 —1370Ì2

-100.0~500.0'C

-328 — 2498*F

-148.0- 932.0’F

J

-200 —1100*c

-328-2012’F

H cc

-200- 400‘c

0-1760C

-100.0~400.0C

-328- 752’F

32 - 3200T

-148.0 -752.0'F ___________________

H cc

-200- 400‘c

0-1760C

-100.0~400.0C

-328- 752’F

32 - 3200T

-148.0 -752.0'F ___________________

 

* Switches automatically to TC resolution range when measured temperatures fall outside the o.rc resolution range.

 

Model

HD-12*1             HD-13*1

HD-12*2             HD-13*2

Rate

lmV/C

lomwr

Range

All range at ir resolution

All range ato.rc resolution

Resistance

100Q

Accuracy

± (0.15% of F/S 4-1 mV) at 25t ±5t

± (0.15% of F/S +1mV) ± (0.01% of F/S) except 25t±5C

 